Name:
|
High Energy Spark Igniter D-HG 400 |
|
Kind:
|
Boiler Intrumentation Produs |
|
Group: |
Durag |
|
Specification: |
- Ignition of liquid or gas fuels in high-capacity industrial burners
|
- Compact design: control unit and ignition lance as one modular unit
|
- Available as explosion-proof model with separate ignition lance
|
- Retraction unit D-VE 404 for automatic burner ignition
|
- Available with 5/8 inch lance as direct replacement for Peabody TM and Forney TM systems.
|
- Portable unit with battery pack also available
|
- Dry contact or pushbutton start units available
|
|
|
Details... |
|
|
 |
Name:
|
Combustion Automation Units and Flame Monitors D-GF 55, D-UV 55-10, D-IR 55-10, D-IO 55-10 |
|
Kind:
|
Boiler Intrumentation Produs |
|
Group: |
Durag |
|
Specification: |
- For intermittent operation
|
- Low cost combustion automation units and flame monitors without self-check
|
- Regulation and Monitoring of oil- and gas-burners with intermittent operation
|
|
|
- Meets the requirements of UL 372 and FM Class 7610
|
|
|
Details... |
|
|
 |
Name:
|
All-In-One Flame Scanner D-LX 100 |
|
Kind:
|
Boiler Intrumentation Produs |
|
Group: |
Durag |
|
Specification: |
-
Main application at industrial single burners with continuous or intermittent operation, e.g. in chemical industries, refineries or cement plants
-
New semiconductor technology with highest sensitivity replaces UV tube for UV flame detection
-
Compact design, flame scanner and amplifier built as one unit, therefore, no space is needed inside a cabinet
-
Self-checking and failsafe according to UL 372, FM 7610 as well as EN 230 and EN 298
-
Housing meets NEMA 4x (IP 67).
-
Relay output contact for direct control of the fuel valve and for status display
-
Programmable flame recognition threshold
-
Analog output for flame intensity
0/4 - 20 mA
-
Fulfills EMC guidelines IEC 555 and IEC 1000 as well as EN 50 081 and EN 50 082
|
|
|
Details... |
|
|
 |
Name:
|
Flame Sensors D-LE 100/101 and D-LE 600/601 |
|
Kind:
|
Boiler Intrumentation Produs |
|
Group: |
Durag |
|
Specification: |
-
Flame sensors for every spectral range of flame monitoring from
UV to IR
-
Connection to the control units
D-UG 110 and D-UG 600 and to programming units D-GF 100
and D-GF 200
-
Uniform output signal thus mutually interchangeable
-
Adjustable to differing combustion conditions, e.g. combustion of
waste gas
|
|
|
Details... |
|
|
 |
Name:
|
Flame Scanner Control System D-UG 660 |
|
Kind:
|
Boiler Intrumentation Produs |
|
Group: |
Durag |
|
Specification: |
-
Monitoring of flames in the UV and IR range (depending on the flame scanner of the series D-LE 100/D-LE 101 or D-LE 600/D-LE601)
-
Sensitivity adjustable in 3 ranges and 100 steps
-
Flame intensity displayed in percent
-
Pulse frequency indication for flame stability monitoring
-
TÜV approved for oil/gas continuous operation for 72 operating hours without capacity limitations
-
UL and FM listed
|
|
|
Details... |
|
|
 |
Name:
|
Flame Sensor D-LE 701/703 with
Fiber Optic System D-LL 702/703/704 |
|
Kind:
|
Boiler Intrumentation Produs |
|
Group: |
Durag |
|
Specification: |
-
Optical flame sensor with fiber optics for various spectral ranges, from UV to IR
-
Typical applications include:
- Tiltable bucket burners
- Cylindrical rotary kilns
- Burners with narrow sighting tubes
- Burners with very high ambient temperatures around the sighting tube
- Burners in which the view from the sighting tube is obscured by high particulate levels
-
Can be used in conjunction with the D-UG 110/120/660 controllers and D-GF 100/200 combustion automation unit
-
Uniform output signal thus mutually interchangeable
-
Can be adjusted for different combustion conditions, e.g., flue
gas recirculation
-
Corresponds to current American and European safety requirements for flame monitoring equipment
|
|
|
Details... |
|
|
 |
Name:
|
Opacity Monitor D-R 290 |
|
Kind:
|
D-R 290 Technical Specifications |
|
Group: |
Durag |
|
Specification: |
-
Makes continuous in situ measurements
-
Solid state light source for long-life
-
Optimizes signal analysis due to the wide emission spectrum of the Super Broadband Light Source. Measurements are more stable than with conventional LED systems under fluctuating temperatures.
- High performance microprocessor technology
- LCD for opacity or optical density is calibrated in mg/m3
- Automatic zero and span check correct for build-ups of impurities
- Completely sealed, rugged optics and electronics contained in a hermetically
sealed housing
- Simple alignment without special tools or laptop
- Advanced purge air system uses less air and reduces maintenance
- Programmable from either the control display unit or remote bus interface
- Data available as analog current or via
bus interface
- Two analog output signals with adjustable measurement ranges
- No continuously moving parts
- Explosion-proof model available
- Built-in filter holder for quarterly audits and
on-stack display allow one-person auditing
- State-of-the-art single board electronics in
stack-mounted receiver employs a single light source and detector
- Data available as current loop or via bus interface with wire or fiber optics
|
|
|
Details... |
|
|
 |
Name:
|
Filter Monitor D-FW 230 / D-FW 231 |
|
Kind:
|
D-R 290 Technical Specifications |
|
Group: |
Durag |
|
Specification: |
-
Filter monitoring based on the triboelectric measuring principal
-
Ideal for bag house monitoring
-
Continuous in-situ measuring
-
Adjustable integration time
-
Compact design
-
Sturdy construction; no moveable parts
-
Easy, straight forward installation and operation
-
Fast on-line performance check capability
-
Minimal maintenance requirements
-
Early detection of filter malfunction
-
Reduces filter replacement costs
|
|
|